The LW26 sereies rotary switch mainly applies to 440V and below,AC 50Hz or 240V and below DC circuits.For breaking and closing,change-over of circuits under unfrequenly manual operation.And the typical application are:control switch of 3 phase motors,control switch gear,control switch of instruments,and change-over switch of machinery and welding machine.
The series comply with the GB 14048.3,GB 14048.5 and IEC 60947-3,IEC 60947-5-1.
The LW26 series have 7 current ratings:10A,20A,25A,32A,63A,125A and 160A.
The LW26 series rotary switch were designed for multiple functions,wide variety of appli -cations.
The LW26-10,LW26-20,LW26-25,and LW26-32F have finger protection terminals.
LW26 series rotary switch are an excellent substitute for LW2,LW5,LW6,LW8,LW12,LW15,HZ5, HZ10,and HZ12.
The LW26 series rotary switch has two derivatives,LW26GS Pad-lock and LW26S lock.
Both of them are applicable in circuits when an physical control is required.
We can equip protective box for 20A,25A,32A and 63A.











Mechanical life
Mechanical life without load:0.3×106times,operation frequency is 300 times/h..
Mechanical life with load:AC-15 DC-13 to 0.01×104times operation frequency is 300 times/h.
AC-3 to 0.1×104times operation frequency is 120 times/h.
AC-4 to 0.1×104times operation frequency is 120 times/h.
rotary switch cam switch changeover switch
Introduction
The LW26 sereies rotary switch mainly applies to 440V and below,AC 50Hz or 240V and below DC circuits.For breaking and closing,change-over of circuits under unfrequenly manual operation.And the typical application are:control switch of 3 phase motors,control switch gear,control switch of instruments,and change-over switch of machinery and welding machine.
The series comply with the GB 14048.3,GB 14048.5 and IEC 60947-3,IEC 60947-5-1.
The LW26 series have 7 current ratings:10A,20A,25A,32A,63A,125A and 160A.
The LW26 series rotary switch were designed for multiple functions,wide variety of appli -cations.
The LW26-10,LW26-20,LW26-25,and LW26-32F have finger protection terminals.
LW26 series rotary switch are an excellent substitute for LW2,LW5,LW6,LW8,LW12,LW15,HZ5, HZ10,and HZ12.
The LW26 series rotary switch has two derivatives,LW26GS Pad-lock and LW26S lock.
Both of them are applicable in circuits when an physical control is required.
We can equip protective box for 20A,25A,32A and 63A.
Description | LW26-10 | LW26-20 | LW26-25 | LW26-32 | LW26-63 | LW26-125 | LW26-160 | |||||||||||||
Rated insolation voltage | Ui | V | 660 | 660 | 660 | 660 | 660 | 660 | 660 | |||||||||||
Rated thermal current | Ith | A | 10 | 20 | 25 | 32 | 63 | 125 | 160 | |||||||||||
Rated working voltage | Ue | V | 240 | 440 | 24 | 110 | 240 | 440 | 24 | 110 | 240 | 440 | 240 | 440 | 240 | 440 | 240 | 440 | 240 | 440 |
Rated working current | Ie | 20 | 20 | |||||||||||||||||
AC-21A AC-22A | A | 10 | 10 | 25 | 25 | 32 | 32 | 63 | 63 | 100 | 100 | 150 | 150 | |||||||
AC-23A | A | 7.5 | 7.5 | 15 | 15 | 22 | 22 | 30 | 30 | 57 | 57 | 90 | 90 | 135 | 135 | |||||
AC-2 | A | 7.5 | 7.5 | 15 | 15 | 22 | 22 | 30 | 30 | 57 | 57 | 90 | 90 | 135 | 135 | |||||
AC-3 | A | 5.5 | 5.5 | 11 | 11 | 15 | 15 | 22 | 22 | 36 | 36 | 75 | 75 | 95 | 95 | |||||
AC-4 | A | 1.75 | 1.75 | 3.5 | 3.5 | 6.5 | 6.5 | 11 | 11 | 15 | 15 | 30 | 30 | 55 | 55 | |||||
AC-15 | A | 2.5 | 2.5 | 5 | 4 | 8 | 5 | 14 | 6 | |||||||||||
AC-13 | A | 12 | 0.4 | 0.4 | 20 | 0.5 | 0.5 | |||||||||||||
power | P | |||||||||||||||||||
AC-23A | KW | 1.8 | 3 | 3.7/2.5 | 7.5/3.7 | 5.5/3 | 11/5.5 | 7.5/4 | 15/7.5 | 15/10 | 30/18.5 | 30/15 | 45/22 | 37/22 | 75/37 | |||||
AC-2 | KW | 2.5 | 3.7 | 4 | 7.5 | 5.5 | 11 | 7.5 | 15 | 18.5 | 30 | 30 | 45 | 37 | 55 | |||||
AC-3 | KW | 1.5 | 2.2 | 3/2.2 | 5.5/3 | 4/3 | 7.5/3.7 | 5.5/4 | 11/5.5 | 11/6 | 18.5/11 | 15/7.5 | 30/13 | 22/11 | 37/18.5 | |||||
AC-4 | KW | 0.37 | 0.55 | 0.55/0.75 | 1.5/1.5 | 1.5/1.1 | 3/2.2 | 2.7/1.5 | 5.5/3 | 5.5/2.4 | 7.5/4 | 6/3 | 12/5.5 | 10/4 |











Mechanical life
Mechanical life without load:0.3×106times,operation frequency is 300 times/h..
Mechanical life with load:AC-15 DC-13 to 0.01×104times operation frequency is 300 times/h.
AC-3 to 0.1×104times operation frequency is 120 times/h.